Translate to:

Low NOx / Ultra-Low NOx Burners
INDUSTRIAL-DUTY DESIGN

SINGLE SOURCE SOLUTIONS

VISION® ProSelect burners provide outstanding emissions reduction metrics. They’re an integral component of the Victory Energy Sustainable Solutions promise. There are 7 models across a deep product offering that deliver a wide range of low NOx / ultra-low NOx emissions performance that meet the toughest sustainability application challenges.

Victory Energy’s ability to design, engineer, manufacture and integrate the combustion systems in combination with the steam generation requirements are unique. The benefits of working with a single source for the entire burner and boiler system will enhance efficiencies and maintenance practices.

The complete line of VISION ProSelect burners in tandem with the proven line of Victory Energy Firetube boilers deliver a vertically integrated package that is setting new standards in the boiler industry.

Ideal for retrofit applications and new installments.



VISION ProSelect SERIES BURNER
  • Standardized Design Selection
  • 100 HP to 2500 HP Capacity
  • 7 Models / Packages
  • <9 ppm NOx  with FGR – Gas
  • <30 ppm NOx with FGR – Gas
  • <75 ppm NOx with FGR – Oil
  • Low CO2, CO, VOC and PM
  • High Fuel Turn Down with High Efficiency
    – Gas: 10.1
    – Oil: 8.1 

VISION ProSelect SERIES DOOR
  • Large viewport
  • Unparalleled Visual Inspection of the Flame Core
  • Furnace Access door

SPARKMAX IGNITER
  • Standard Equipment
  • NFPA CLASS 1, 2 OR 3 GAS IGNITER
    – Capacity ranges from 0,25 MMBtu/hr to 40 MMBtu/hr

    – Standard to severe-duty environments

    – 99% ignition rate in most applications
    – Highly reliable ignition enhanced by quick Premix Combustion


QUICK LINKS

FULLY INTEGRATED WITH VICTORY ENERGY FRONTIER FIRETUBE BOILERS

VISION PROSELECT MODEL ID
BOILER (HP)
MAX HEAT INPUT (MMBTU/HR
EMISSIONS (PPM)
FUEL(S)
VPS-FS1-LN
100 - 150
4.2 - 6.3
<30
GAS / LIQUID
VPS-FS2-LN
200 - 300
8.1 - 12.1
<30
GAS / LIQUID
VPS-FS3-LN
350 - 500
14.1 - 20
<30
GAS / LIQUID
VPS-FS4-LN
600 - 900
24 - 36
<30
GAS / LIQUID
VPS-FS5-LN
1000 - 1400
40 - 55.9
<30
GAS / LIQUID
VPS-FS6-LN
1500 - 2000
59.8 - 79.9
<30
GAS / LIQUID
VPS-FS7-LN
2200 - 2500
87.9 - 99.8
< 30
GAS / LIQUID
VISION PROSELECT MODEL ID
BOILER (HP)
MAX HEAT INPUT (MMBTU/HR
EMISSIONS (PPM)
FUEL(S)
VPS-FS1-ULN
100 - 150
4.2 - 6.3
<9
GAS / LIQUID
VPS-FS2-ULN
200 - 300
8.1 - 12.1
<9
GAS / LIQUID
VPS-FS3-ULN
350 - 500
14.1 - 20
<9
GAS / LIQUID
VPS-FS4-ULN
600 - 900
24 - 36
<9
GAS / LIQUID
VPS-FS5-ULN
1000 - 1400
40 - 55.9
<9
GAS / LIQUID
VPS-FS6-ULN
1500 - 2000
59.8 - 79.9
<9
GAS / LIQUID
VPS-FS7-ULN
2200 - 2500
87.9 - 99.8
<9
GAS / LIQUID